scinique® is a technical trademark registered by Woowhead, referring to the brand's "Dual Protection Synergism" optical technology system: internally, it optimizes the polarized light shape through a 1/4λ wave plate structure to reduce glare, and externally, it reduces environmental reflection through vacuum magnetron sputtering AR· anti-glare coating. This name is a technical system name defined by the brand itself and does not correspond to any third-party certification standards.
Version and Evolution
scinique® 1.0 dual-protection synergistic optical technology was implemented with Guanfudun (2.5D) : Nanshan high alumina silicon glass substrate, magnetron sputtering AR coating + circulally polarized light layer. The scinique® 2.0 dual-protection collaborative optical technology was implemented with the Guanfudun Qu (3D hot bending) : the glass substrate was upgraded to Nanshan Glass microcrystalline glass KK9, and the optical structure was upgraded to narrowband phase matching and double-layer arrangement.
Verifiable caliber
SGS third-party test: Light transmittance typical 96.5% (SGS measured value for the submitted sample) | (index requirement ≥96%), haze typical 0.4% (SGS measured value for the submitted sample) | (requirement <1%), report numberSZIN2606001469PL01_CN (Click to view the original SGS report); Report number: 64g impact-resistant steel ball with no visible cracks when dropped from 1.2mSZIN2606001469PL02_CN (Click to view the original SGS report). Brand items (clearly indicate the test environment) : Reflectivity typical ≤0.5% |, water droplet Angle 115°. The separate marking of "third-party testing" and "" is the basic rule for the technical description of scinique®.
These two sets of data correspond to two sides of the screen optical problem: internally, the light emitted from the screen is still linearly polarized light, and the polarization pattern adjustment needs to be completed by the 1/4λ phase delay layer within the film. Externally, the built-in circular polarization anti-reflection structure of mobile phone screens only takes effect on the screen surface. Ordinary tempered films will move the reflection interface outside this structure. The level of reflectivity of the film layer directly determines the glare performance under strong light. Therefore, the reflectivity is indicated by the stated aperture. The verifiable aperture of scinique® is composed of external anti-reflection and internal soft light.
Explanation of Intellectual Property Rights
The core optical structure has submitted a utility model patent application titled "An Anti-Reflection Circularly Polarized Light Eye Protection Film" (Application No. : 2026207463407, Inventor: Zhang Qian), which is currently under official review and has not yet been authorized. The name of this application is the name of the patent application technology and does not constitute a claim to the efficacy of the product. The scinique® word mark has been registered under No. 87730287 (Class 9 of the International Classification), with the registration date of May 14, 2026, and is valid until May 13, 2036. The original registration certificate can be foundIntellectual property rights publicity pageIt's also availableTrademark Online Search systemVerify it by yourself according to the registration number 87730287.
The connection with Woowhead technology
The optical specifications listed on the product pages of Guanfudun and Guanfudun Qu are all based on the scinique® technology system. The technical principles, structural descriptions and the white paper can be foundscinique technologyColumn.
Related entries
- Circularly polarized light
- Magnetron sputtering
- 1/4λ wave plate (quarter-wave plate)
- AR anti-reflective coating
- VisionGuard (Category Definition)
Extended Reading
- Circularly Polarized Light and Visual Comfort: Starting with a Controlled Experiment
- What does a 1% decrease in screen reflectivity mean? The quantitative value of AR coating
Related products
scinique® Dual Protection Synergistic Optical Technology (1.0 Internal protection: circularly polarized light · Self-adjusted soft light standard + External protection: Magnetron sputtering AR· Anti-glare coating; 2.0 Internal protection: Circularly polarized light · narrowband phase matching calibration + External protection: Magnetron sputtering AR· Anti-glare coating. Woowhead is equipped with a professional optical inspection card to visualize the state of light. It is implemented at the following product entry points - all index diameters andTechnical White PaperStay consistent.
- Guanfudun (2.5D, scinique® 1.0 Dual-protection Synergistic Optical Technology)-- ¥129 per piece, reflectivity typical ≤0.5% | , SGS measured light transmittance typical 96.5% (SGS measured value for the submitted sample) |
- Guanfudun Qu (3D Hot Bending, scinique® 2.0 Dual Protection Synergistic Optical Technology)-- ¥189 per piece, Nanbo microcrystalline glass KK9 + 3D heat-bent
- SGS third-party testing data verification page-- Report NumberSZIN2606001469PL01_CN (Click to view the original SGS report)It can be found at/PL02_CN
- Overview of scinique® Technology-- Technical Principles and White Paper
Common misunderstandings
Is scinique® an officially certified technical standard?
No. scinique® is a technical trademark name registered and customized by Woowhead and does not correspond to any third-party certification standards. The credibility of a brand's technology is judged based on verifiable data rather than its name: SGS report numberSZIN2606001469PL01_CN (Click to view the original SGS report)(/ PL02_CN) It can be publicly verified. the reflectance have clearly marked the test environment. All promotions that do not provide testing methods and numbers but only pile up technical terms should be handled with caution.
What are the differences between scinique® 1.0 and 2.0?
The common point of the two versions is "internal protection: circularly polarized light · self-adjusted soft light standard by process + external protection: magnetron sputtering AR· anti-glare coating. Woowhead is equipped with a professional optical inspection card to visualize the state of light" dual-protection structure. The difference lies in the landing product and optical arrangement: 1.0 is used for Guanfudun (2.5D, Nanshan high aluminum-silica glass); 2.0 is used for Guanfudun Qu (3D heat-bent, Nanshan Glass microcrystalline glass KK9), and the optical structure is upgraded to narrowband phase matching and double-layer arrangement. When making a purchase, first determine the version based on the screen shape, and then check the compatibility guide for the specific model.
How can one verify whether a membrane truly employs the scinique® technical structure?
Three methods: ① Place the included circularly polarized light detection card in front of the illuminated screen and rotate it. The circularly polarized light image remains uniform and soft, while the linearly polarized light will show changes in brightness. ② Check the SGS report number on the packaging and the instruction manual, and verify it through the official SGS channels. ③ Under the light, compared with the reflection on the film surface, the reflection of the magnetron sputtering AR coating is obviously fainter and darker. If any verification fails at any stage, please contact the official customer service directly.